{"product_id":"microlife-thermometer-pen-10-seconden-flextip-mt200-1-stuks","title":"Microlife Thermometer pen 10 seconds flextip MT200 1 Piece","description":"\u003cb\u003eMicrolife Thermometer pen 10 seconds flextip MT200\u003c\/b\u003e\u003cbr\u003e \u003cbr\u003eMicrolife Thermometer pen 10 seconds flextip MT200\u003cbr\u003e\u003cbr\u003e High-Speed ​​Digital Thermometer\u003cbr\u003e • Highest accuracy in 10 seconds\u003cbr\u003e • Flexible tip\u003cbr\u003e • Hypoallergenic tip\u003cbr\u003e Technical specifications\u003cbr\u003e Type: Maximum thermometer\u003cbr\u003e Measuring range: 32.0 °C to 42.9 °C\u003cbr\u003e Temp. \u0026lt; 32.0 °C: display «L» for low (too low)\u003cbr\u003e Temp. \u0026gt; 42.9 °C: display «H» for high (too high)\u003cbr\u003e Measurement accuracy: ± 0.1 °C between 34 °C and 42 °C\u003cbr\u003e ± 0.2 °C; 32.0 - 33.9 °C and 42.1 - 42.9 °C\u003cbr\u003e Operating conditions: 10–40 °C; 15–95% maximum relative humidity\u003cbr\u003e Storage conditions: -25 - +60 °C; 15-95 % maximum relative humidity\u003cbr\u003e Battery: LR41 (1.5V) \/ SR41 (1.55V)\u003cbr\u003e Battery life: approximately 2700 measurements (with a new battery)\u003cbr\u003e IP Class: IP67\u003cbr\u003e Reference to standards: EN 12470-3, clinical thermometers;\u003cbr\u003e ASTM E1112; IEC 60601-1; IEC 60601-1-2 (EMC);\u003cbr\u003e IEC 60601-1-11\u003cbr\u003e Expected lifespan: 5 years or 10,000 measurements\u003cbr\u003e - clinically tested\u003cbr\u003e This device complies with the standards of the Medical Device Directive\u003cbr\u003e aids 93\/42\/EEC.\r \u003cbr\u003eTechnical changes reserved.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eWhat is this medicine used for?\u003c\/b\u003e\u003cbr\u003e Measuring body temperature\u003cbr\u003e\u003cbr\u003e \u003cb\u003eDirections for use\u003c\/b\u003e\u003cbr\u003e Turn on the thermometer\u003cbr\u003e To turn on the thermometer, press the ON\/OFF button 1; a\u003cbr\u003e A short beep indicates that the thermometer is switched on. A display test\u003cbr\u003e in progress. All function options are displayed.\u003cbr\u003e The last measurement will automatically be shown on the display 2\u003cbr\u003e for 2 seconds with the \"M\" symbol.\u003cbr\u003e At a room temperature of less than 32 °C, the\u003cbr\u003e symbol «L» in the display, then the symbol «°C» flashes in\u003cbr\u003e the display 2. The thermometer is now ready for use.\u003cbr\u003e Function test\u003cbr\u003e The thermometer's operation is automatically tested every time\u003cbr\u003e when it is turned on. If a defect is detected\u003cbr\u003e (measurement inaccurate), this is indicated by \"ERR\" in the\u003cbr\u003e display, and measuring is no longer possible. In this case, the thermometer must\u003cbr\u003e are replaced.\u003cbr\u003e\u003cbr\u003e Using the thermometer\r \u003cbr\u003eSelect the desired measurement method. During measurement, the current\u003cbr\u003e temperature is displayed continuously and the «°C» symbol flashes.\u003cbr\u003e If a beep sounds 10 times and the \"°C\" no longer flashes, then the\u003cbr\u003e temperature measured and can be read.\u003cbr\u003e When the temperature is higher than 37.5 °C, 10 beeps will sound\u003cbr\u003e to alert the patient that he\/she may have a fever\u003cbr\u003e have. Reference: Orally measured temperature.\u003cbr\u003e To compare measurement results you must wait at least 1 minute\u003cbr\u003e to measure interval.\u003cbr\u003e To extend battery life, you can use the thermometer\u003cbr\u003e switch off by briefly pressing the ON\/OFF button 1. Otherwise, the\u003cbr\u003e thermometer switches off automatically after approximately 10 minutes.\u003cbr\u003e\u003cbr\u003e Measurement methods \/ Normal body temperature\u003cbr\u003e  Under the armpit (auxillary) \/ 34.7 - 37.3 °C\u003cbr\u003e Pat your armpits dry with a towel. Place the measuring sensor\u003cbr\u003e 4 under the arm in the middle of the armpit, so that the point touches the skin\u003cbr\u003e touch and place the arm next to the body. This ensures that the\r \u003cbr\u003eroom temperature does not affect the measurement, because the armpit is more\u003cbr\u003e needs time to reach a temperature. Wait 5 minutes,\u003cbr\u003e regardless of the beeping sound.\u003cbr\u003e  In the mouth (oral) \/ 35.5 - 37.5 °C\u003cbr\u003e Do not eat or drink anything hot or cold 10 minutes before the measurement. The mouth\u003cbr\u003e must remain closed until 2 minutes before starting the measurement.\u003cbr\u003e Place the thermometer under the tongue, to the left or right of the frenulum.\u003cbr\u003e The tip of the thermometer should make good contact with\u003cbr\u003e the tissue 4. Close your mouth and breathe evenly through your nose to\u003cbr\u003e to prevent the measurement from being influenced by breathing via\u003cbr\u003e the mouth.\u003cbr\u003e If this is not possible due to blocked airways,\u003cbr\u003e a different measurement method must be used.\u003cbr\u003e Measuring time approx.: 10 seconds!\u003cbr\u003e  In the anus (rectal) \/ 36.6 - 38.0 °C\u003cbr\u003e Carefully insert the thermometer's measuring sensor 4 2 to 3 cm\u003cbr\u003e in the anal opening.\u003cbr\u003e The use of a protective cap and the use of Vaseline is\u003cbr\u003e recommended.\u003cbr\u003e If you are unsure about this measurement method, consult a professional\r \u003cbr\u003eto be consulted for guidance\/training.\u003cbr\u003e Measuring time approx.: 10 seconds!\u003cbr\u003e\u003cbr\u003e Cleaning and disinfecting\u003cbr\u003e For disinfection in a home environment, use a cotton swab of\u003cbr\u003e 70% isopropyl alcohol or a cotton swab moistened with\u003cbr\u003e 70% isopropyl alcohol to remove dirt from the thermometer probe.\u003cbr\u003e sweep (note: consider application and safety instructions of\u003cbr\u003e the disinfectant manufacturer). Always start by wiping\u003cbr\u003e from the end of the thermometer probe (approximately in the middle\u003cbr\u003e of the thermometer) towards the thermometer tip. Then the\u003cbr\u003e entire thermometer probe (see number 5 in the drawing)\u003cbr\u003e immersed in 70% isopropyl alcohol for at least 70% 5\u003cbr\u003e minutes (max. 24 hours). Allow the disinfectant to dry after immersion.\u003cbr\u003e Dry for 1 minute before next use. Soak or wipe it\u003cbr\u003e do not screen to prevent blurring.\u003cbr\u003e The thermometer is not intended for professional use.\u003cbr\u003e\u003cbr\u003e When the symbol «» appears on the display, the battery is\r \u003cbr\u003eempty and needs to be replaced. To replace the battery\u003cbr\u003e the battery compartment cover must be removed 3. Place\u003cbr\u003e a new battery with the + side on top. Make sure you have a\u003cbr\u003e battery of the same type at hand. Batteries can be used in almost\u003cbr\u003e all electronics stores are bought.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eIngredients\u003c\/b\u003e\u003cbr\u003e Thermometer\u003cbr\u003e\u003cbr\u003e \u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003e Follow the instructions for proper use. This documentation provides you with important operating and safety instructions for this appliance. Read this documentation carefully before using the appliance and keep it for future reference.\u003cbr\u003e - This device is only to be used for measuring human body temperature via oral, rectal or axillary routes.\u003cbr\u003e Do not attempt to take temperatures in other places, such as in the ear, as this may lead to inaccurate measurements and injury.\u003cbr\u003e - Do not use this appliance if you suspect it is damaged or if you notice anything unusual.\r \u003cbr\u003e- We recommend cleaning this appliance according to the cleaning instructions before first use for personal hygiene.\u003cbr\u003e - The measuring time until the sound signal must be adhered to as a minimum without exception!\u003cbr\u003e - Please note that multiple measurements may be required for different measurement locations even after the beep\u003cbr\u003e Do not attempt rectal measurements on individuals with rectal conditions. This may worsen the condition.\u003cbr\u003e - Only allow children to use the appliance under adult supervision. Small parts can be swallowed. Be aware of the risk of entanglement if the appliance is equipped with cables or hoses.\u003cbr\u003e Do not use the device near strong electromagnetic fields, such as those from mobile phones or radios. Maintain a distance of at least 3.3 meters from such devices when using this device.\u003cbr\u003e - Protect the instrument from shocks and falls!\u003cbr\u003e - Do not bend the thermometer probe more than 45°!\r \u003cbr\u003eAvoid ambient temperatures above 60°C. NEVER boil the instrument!\u003cbr\u003e - Only use the disinfectants listed in the Cleaning and Disinfecting section to clean the device to avoid damage to the device.\u003cbr\u003e We recommend having this device tested for accuracy every two years or after mechanical impact (e.g., dropping). Contact your local Microlife dealer for this.\u003cbr\u003e\u003cbr\u003e WARNING: The temperature measured with this device is not a diagnostic! Do not rely solely on the measured result.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eStorage advice\u003c\/b\u003e\u003cbr\u003e Batteries and electronic instruments should be disposed of according to local regulations and not with household waste.\u003cbr\u003e\u003cbr\u003e Store at a temperature between -25°C and 60°C\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOther information\u003c\/b\u003e\u003cbr\u003e Warranty\u003cbr\u003e This appliance has a lifetime warranty from the date of purchase.\u003cbr\u003e During this warranty period, Microlife will replace the defective product free of charge.\u003cbr\u003e repair or replace.\u003cbr\u003e Opening or modifying the device will void the warranty.\u003cbr\u003e invalid.\r \u003cbr\u003eThe following items are excluded from the warranty:\u003cbr\u003e - Transportation costs and transportation risks.\u003cbr\u003e - Damage caused by improper use or non-compliance with the\u003cbr\u003e instructions for use.\u003cbr\u003e - Damage caused by leaking batteries.\u003cbr\u003e - Damage caused by dropping or misuse.\u003cbr\u003e - Packaging\/storage material and instructions for use.\u003cbr\u003e - Regular checks and maintenance (calibration).\u003cbr\u003e - Accessories and consumables: Battery.\u003cbr\u003e If warranty is required, please contact the dealer where you purchased it.\u003cbr\u003e product you purchased, or with your local Microlife service.\u003cbr\u003e\u003cbr\u003e You can via\u003cbr\u003e Contact your local Microlife dealer via our website:\u003cbr\u003e www.microlife.com\/support\u003cbr\u003e The compensation is limited to the value of the product. The warranty\u003cbr\u003e will be granted if the complete product is returned with the\u003cbr\u003e Original invoice. Repair or replacement within the warranty period\u003cbr\u003e or does not extend the warranty period. The statutory claims and rights\u003cbr\u003e of consumers are not limited by this warranty. \u003cbr\u003eMedical device. Read the instructions for use before use.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eManufacturer \/ Distributor\u003c\/b\u003e\u003cbr\u003e Microlife Corporation,\n 9F, 431 RuiGuang Road ,\n NeiHu Taipei,\n 11492 Taiwan,\n China","brand":"Microlife","offers":[{"title":"1.00 Stuks","offer_id":57994163159385,"sku":"788909","price":11.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0971\/4843\/6825\/files\/4719003070021_A1N1.png?v=1781796877","url":"https:\/\/cleanpharma.nl\/en\/products\/microlife-thermometer-pen-10-seconden-flextip-mt200-1-stuks","provider":"CleanPharma","version":"1.0","type":"link"}