{"product_id":"microlife-non-contact-thermometer-nc200-1-stuks","title":"Microlife Non-contact thermometer NC200 1 Piece","description":"\u003cb\u003eMicrolife Non-contact thermometer NC200\u003c\/b\u003e\u003cbr\u003e \u003cbr\u003eThis Microlife thermometer is a high-quality product featuring the latest technology and tested to international standards. Its unique technology allows it to deliver stable readings free from heat interference with every measurement. Each time the thermometer is turned on, it automatically performs a self-test to ensure measurement accuracy.\u003cbr\u003e\u003cbr\u003e This thermometer has been clinically tested and found to be safe and accurate when used in accordance with\u003cbr\u003e with its instructions for use.\u003cbr\u003e\u003cbr\u003e Technical specifications\u003cbr\u003e Type: Custom mode non-contact thermometer NC 200\u003cbr\u003e Mode type: Adjustable mode\u003cbr\u003e Measurement site: Forehead\u003cbr\u003e Reference to body site: Under the tongue\u003cbr\u003e Measuring range: Body mode: 34.0 - 43.0 °C \/ 93.2 - 109.4 °F\u003cbr\u003e Object mode: 0.1 - 99.9 °C \/ 32.2 - 211.8 °F\u003cbr\u003e Resolution: 0.1 °C \/ °F\u003cbr\u003e Storage conditions: -25 - +55 °C \/ -13 - +131 °F\u003cbr\u003e 15 - 95 % maximum relative humidity\r \u003cbr\u003eAuto power off: Approximately 1 minute after last measurement.\u003cbr\u003e Battery: 2 x 1.5V alkaline batteries; type AAA\u003cbr\u003e Battery life: approximately 2000 measurements (with new batteries)\u003cbr\u003e Dimensions: 156.7 x 43 x 47 mm\u003cbr\u003e Weight: 91.5g (with battery), 68.5g (without battery)\u003cbr\u003e IP Class: IP22\u003cbr\u003e Reference to\u003cbr\u003e standards: ISO 80601-2-56; IEC 60601-1; IEC 60601-1-2 (EMC)\u003cbr\u003e Expected lifespan: 5 years or 12,000 measurements\u003cbr\u003e - Measure in seconds\u003cbr\u003e - The innovative infrared technology allows a measurement to be completed without contact with the body. This guarantees\u003cbr\u003e a safe and hygienic measurement within seconds.\u003cbr\u003e - Automatic measurement with distance control\u003cbr\u003e This device can automatically perform a measurement when the\u003cbr\u003e desired distance within 5 cm is reached.\u003cbr\u003e - Multiple applications (large measuring range)\u003cbr\u003e This thermometer has a wide measuring range of 0.1 - 99.9 °C \/\u003cbr\u003e 32.2 - 211.8 °F; the thermometer can be used to measure the\u003cbr\u003e to measure body temperature, but can also be used\r \u003cbr\u003efor measuring the surface temperature of:\u003cbr\u003e - Milk in a baby's bottle\u003cbr\u003e -The water in a baby's bath\u003cbr\u003e - The ambient temperature\u003cbr\u003e\u003cbr\u003e Accurate and reliable\u003cbr\u003e The unique probe head with built-in advanced infrared sensor ensures that every measurement is accurate and reliable.\u003cbr\u003e\u003cbr\u003e User-friendly and easy to use\u003cbr\u003e - The ergonomic design makes the thermometer handy and easy to use.\u003cbr\u003e - This thermometer can even be used on a sleeping child, who can sleep peacefully.\u003cbr\u003e - This thermometer is fast and therefore pleasant to use for children.\u003cbr\u003e - Read back multiple measurements\u003cbr\u003e - Users can view the last 30 measurements by turning on the memory mode. This allows you to easily\u003cbr\u003e follow temperature variations.\u003cbr\u003e\u003cbr\u003e Safe and hygienic\u003cbr\u003e - No direct contact with skin.\u003cbr\u003e - No risk of broken glass or mercury ingestion.\u003cbr\u003e - Completely safe for children.\u003cbr\u003e\u003cbr\u003e Fever alarm\r \u003cbr\u003e- 10 short beeps and a red illuminated LCD alert you when a temperature above 37.5 °C has been measured.\u003cbr\u003e - Tracking system for self-measurement\u003cbr\u003e - A green light on the back shows the user when the correct distance has been reached and a measurement is taken automatically.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eWhat is this medicine used for?\u003c\/b\u003e\u003cbr\u003e The Microlife thermometer is designed to measure and monitor human body temperature.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eDirections for use\u003c\/b\u003e\u003cbr\u003e Take your temperature with this thermometer\u003cbr\u003e The thermometer measures infrared radiation emitted by the forehead or other objects. This energy is captured by the lens and converted into a temperature value.\u003cbr\u003e\u003cbr\u003e Control screen and symbols\u003cbr\u003e All symbols appear 9: Press the START\/IO button to activate the thermometer, all symbols will appear on the display for 1 second.\r \u003cbr\u003eReady for measurement AT: When the thermometer is ready for measurement, the “°C” or “°F” symbol will continue to flash, while the body or object symbol remains displayed.\u003cbr\u003e Countdown before BR measurement: A 3-second countdown is shown on the display (3, 2, 1) before each measurement.\u003cbr\u003e Measurement Complete AK: The measurement will be shown on display 4 with both the ear or forehead symbol and the symbol for «°C» or «°F» remaining displayed.\u003cbr\u003e As soon as the \"°C\" or \"°F\" symbol flashes again, the device is ready for the next measurement.\u003cbr\u003e Low Battery ON: When the thermometer is turned on, the icon will keep flashing to remind you that the batteries need to be replaced.\u003cbr\u003e\u003cbr\u003e Setting date, time and beeper functions\u003cbr\u003e Setting the date and time\u003cbr\u003e After the batteries are installed, the year will flash in the display BO. You can set the year by pressing the M button 5. To confirm and then set the month,\r \u003cbr\u003eTo set, press the MODE button 6.\u003cbr\u003e Now you can set the month with the M button 5. Press the MODE button 6 to confirm and then set the day.\u003cbr\u003e Follow the instructions as described above to set the day, hours and minutes.\u003cbr\u003e Once you have set the minutes and press the START\/IO button 7, the date and time are set and the time is displayed\u003cbr\u003e If no key is pressed for 20 seconds, the thermometer automatically switches to the ready-to-use mode AT.\u003cbr\u003e End time setup: Press the START\/IO button 7 during time setup. The date\/time symbol with \"--:--\" will appear on the LCD screen. Then press the START\/IO button 7 to start the measurement. If you do not do anything else, the thermometer will automatically turn off after 30 seconds.\u003cbr\u003e turn off.\u003cbr\u003e Change the current date and time: Press and hold the MODE button 6 for 8 seconds until the year starts flashing BO. You can now enter the new data as described above.\u003cbr\u003e\u003cbr\u003e Setting the beeper\r \u003cbr\u003ePress and hold the MODE button 6 for 3 seconds to set the BP beeper.\u003cbr\u003e Press the M button 5 to turn the beeper on or off. The beeper is activated when the BP sound symbol appears without a cross.\u003cbr\u003e When the beeper setting is selected, press the START\/IO button 7 for the \"ready for measurement\" mode; otherwise, the device will automatically be ready for measurement after 10 seconds.\u003cbr\u003e\u003cbr\u003e Switching from body mode to object mode\u003cbr\u003e Press the START\/IO button 7. All symbols will appear on the display 4 for 1 second.\u003cbr\u003e The default mode is object mode AL. Press the MODE button 6 to switch to AM mode. To switch back to body mode, press the MODE button again.\u003cbr\u003e\u003cbr\u003e Instructions for use\u003cbr\u003e Always remove the protective cap BS before use.\u003cbr\u003e Measure in body mode with automatic measurement and distance control\u003cbr\u003e 1. Press the START\/IO button 7. All symbols will appear on the display 4 for 1 second.\r \u003cbr\u003e2. A flashing °C\/°F symbol, a flashing blue tracer light 2, and a beep indicate that the device is ready for an AT measurement.\u003cbr\u003e 3. Remove hair, sweat or dirt from the forehead to prevent inaccurate measurements.\u003cbr\u003e 4. Point the thermometer at the center of the forehead, keeping a distance of no more than 5 cm from the forehead.\u003cbr\u003e 5. The device will start automatically when the measuring sensor 1 detects the required distance of less than 5 cm. The display will show a countdown (3, 2, 1); after 3 seconds, a long beep will indicate that the measurement is complete.\u003cbr\u003e 6. Self-measurement: The self-measurement light 3 will help indicate when the measurement starts. Hold the thermometer to your forehead until the light turns off.\u003cbr\u003e 7. Read the measured temperature from the LCD display.\u003cbr\u003e 8. For a follow-up measurement, hold the thermometer away from your forehead and wait until the °C\/°F symbol flashes again. Continue with steps 4-5 above.\r \u003cbr\u003e9. Press and hold the START\/IO button 7 for 3 seconds to turn it off; otherwise, the device will automatically turn off after 60 seconds.\u003cbr\u003e Measuring in object mode without automatic measuring 1. Press the START\/IO button 7. All symbols appear on the display 4 for 1 second.\u003cbr\u003e 2. Press the MODE button 6 to switch to object mode.\u003cbr\u003e 3. A flashing °C\/°F symbol, a flashing blue tracer light 2 and a beep signal indicate that the device is ready for an AT measurement.\u003cbr\u003e 4. Point the thermometer at the center of the object you wish to measure, no more than 5 cm away. Now press the START\/IO button 7. After 3 seconds, a long beep will indicate that the measurement is complete.\u003cbr\u003e 5. Read the measured temperature from the LCD display.\u003cbr\u003e 6. For a subsequent measurement, wait until the °C\/°F symbol flashes again. Continue with steps 4-5 above.\r \u003cbr\u003e7. Press and hold the START\/IO button 7 for 3 seconds to turn it off; otherwise, the device will automatically turn off after 60 seconds.\u003cbr\u003e Patients and thermometer should remain in a room with a constant temperature for at least 30 minutes.\u003cbr\u003e Do not measure during or immediately after feeding a baby.\u003cbr\u003e Do not use the thermometer in rooms with excessive humidity.\u003cbr\u003e Patients should not drink, eat, or exercise before\/during measurement.\u003cbr\u003e Do not remove the measuring device from the measuring area until you hear the end beep.\u003cbr\u003e 10 short beeps and a red illuminated LCD alert you that a temperature above 37.5 °C has been measured.\u003cbr\u003e Always take the temperature in the same place, as temperature readings may vary from place to place.\u003cbr\u003e differences.\r \u003cbr\u003eDoctors recommend taking newborns' temperatures rectally during the first 6 months, as other methods can often lead to unreliable results. If you still want to perform a non-contact temperature measurement on newborns, verify this with a rectal measurement.\u003cbr\u003e In the following circumstances it is recommended to take three measurements and take the highest result:\u003cbr\u003e Children under three years of age with a deficient immune system and in whom the presence or absence of fever is critical.\u003cbr\u003e When the user is first learning to use the thermometer, until he\/she is familiar with the device and obtains regular results.\u003cbr\u003e If the measurement is unexpectedly low.\u003cbr\u003e Temperature measurements should not be compared with each other because body temperature can\u003cbr\u003e fluctuate with time and ambient temperature, often body temperature is highest in the evening and lowest in the morning hours.\u003cbr\u003e\u003cbr\u003e Normal body temperatures are:\u003cbr\u003e Armpit: 34.7 - 37.3 °C \/ 94.5 - 99.1 °F\r \u003cbr\u003eOral: 35.5 - 37.5 °C \/ 95.9 - 99.5 °F\u003cbr\u003e Rectal: 36.6 - 38.0 °C \/ 97.9 - 100.4 °F\u003cbr\u003e Microlife NC 200: 35.4 - 37.4 °C \/ 95.7 - 99.3 °F\u003cbr\u003e\u003cbr\u003e 8. Switchable from Celsius to Fahrenheit\u003cbr\u003e This thermometer displays temperature measurements in Fahrenheit and Celsius. To switch between °C and °F, press and hold the MODE button 6 for 3 seconds; the beeper symbol will appear on the display. Press the MODE button again; the current unit of measure (\"°C\" or \"°F\" symbol) will appear on the display AO. Switch between the units of measure (°C\/°F) by pressing the M button 5. Once the unit of measure has been selected, press the START\/IO button 7 to activate the \"ready for measurement\" mode; otherwise, the device will automatically switch off after 10 seconds AT.\u003cbr\u003e\u003cbr\u003e 9. Recalling 30 measurements in memory mode\u003cbr\u003e This thermometer displays the last 30 measurements, including date and time.\u003cbr\u003e AP Call Mode: Press the M button 5 to enter call mode when the device is off. The \"M\" memory icon flashes.\r \u003cbr\u003eResult 1 – the last result AQ: Press the M button 5\u003cbr\u003e and release it to see the latest result. Screen 1\u003cbr\u003e only with memory symbol.\u003cbr\u003e Pressing and releasing the M button 5 after the last 30 results have been called up will continue the above sequence with result 1.\u003cbr\u003e\u003cbr\u003e 10. Error messages\u003cbr\u003e Measured temperature too high AR: The symbol \"H\" will\u003cbr\u003e appear when the temperature is above 43°C \/ 109.4°F in\u003cbr\u003e the body mode or 99.9 °C \/ 211.8 °F in object mode.\u003cbr\u003e Measured temperature too low AS: The symbol \"L\" will\u003cbr\u003e appear when the temperature is below 34 °C \/ 93.2 °F in the\u003cbr\u003e body mode or 0.1 °C \/ 32.2 °F in object mode.\u003cbr\u003e\u003cbr\u003e Ambient temperature too high BT: The symbol «AH» will appear when the ambient temperature is higher than\u003cbr\u003e 40.0 °C \/ 104.0 °F.\u003cbr\u003e Ambient temperature too low BK: The symbol «AL» will appear when the ambient temperature is lower than 15.0\u003cbr\u003e °C \/ 59.0 °F in Body mode or below 5.0 °C \/ 41.0 °F in Object mode.\u003cbr\u003e\r \u003cbr\u003eError in BL operation:\u003cbr\u003e “Er 0” \/ “Er 6”: The system is not working properly.\u003cbr\u003e Step 2: The device is placed directly on the forehead or object. Maintain a distance of 1-5 cm. Never touch the bottom (sensor area) of the measurement sensor.\u003cbr\u003e Blank screen BM: Please check that the batteries are installed correctly. Also check the polarity (\u0026lt;+\u0026gt; and \u0026lt;-\u0026gt;) of the batteries.\u003cbr\u003e Low battery status BN: If only the icon is shown on the display, replace the batteries immediately.\u003cbr\u003e\u003cbr\u003e 11. Cleaning and disinfecting\u003cbr\u003e Use a cotton swab or a cotton ball soaked in alcohol (70% isopropyl alcohol) to clean the thermometer housing and probe head. Be careful not to get any liquid inside the thermometer. Never use harsh cleaning agents, thinners, or benzene when cleaning, and never immerse the thermometer in water or any other liquid. Be careful not to scratch the surface of the probe lens or the display.\u003cbr\u003e\r \u003cbr\u003e12. Battery Replacement\u003cbr\u003e This instrument is supplied with two long-life 1.5V AAA batteries, which should be replaced immediately when only the BN symbol is displayed.\u003cbr\u003e Remove the battery plate BQ by pushing in the direction shown.\u003cbr\u003e Replace the batteries – check the correct polarity as shown by the symbols in the compartment.\u003cbr\u003e Batteries and electronic instruments should be disposed of according to local regulations and not with household waste.\u003cbr\u003e\u003cbr\u003e See the package insert for button markings and locations.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eIngredients\u003c\/b\u003e\u003cbr\u003e -\u003cbr\u003e\u003cbr\u003e \u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003e Follow the instructions for proper use. This documentation provides you with important operating and safety instructions for this appliance. Read this documentation carefully before using the appliance and keep it for future reference.\u003cbr\u003e\r \u003cbr\u003eThis appliance may only be used for its intended purpose as described in the instructions for use. The manufacturer is not liable for damage caused by improper use.\u003cbr\u003e\u003cbr\u003e Never immerse this appliance in water or other liquids. For cleaning, follow the instructions in the \"Cleaning and Disinfecting\" section.\u003cbr\u003e\u003cbr\u003e Do not use the appliance if you suspect it is damaged or if you notice anything unusual during use.\u003cbr\u003e\u003cbr\u003e Never open the appliance\u003cbr\u003e\u003cbr\u003e A normal biological process called vasoconstriction can occur early in a fever, resulting in a lower skin surface temperature; the temperature measured with a thermometer may then be suspiciously low.\u003cbr\u003e\u003cbr\u003e If the measurement result is not consistent with the patient's finding or is suspiciously low, repeat the measurement every 15 minutes or check the result with another core body temperature measurement.\u003cbr\u003e\r \u003cbr\u003eThis device contains sensitive components and must be handled with care. Follow the storage and operating instructions described in the \"Technical Specifications\" section!\u003cbr\u003e\u003cbr\u003e Only allow children to use the appliance under adult supervision; small parts could be swallowed.\u003cbr\u003e\u003cbr\u003e Do not use the device near strong electromagnetic fields, such as those from mobile phones or radios. Maintain a distance of at least 3.3 meters from such devices when using this device.\u003cbr\u003e\u003cbr\u003e Protect it from:\u003cbr\u003e - extreme temperatures\u003cbr\u003e - shocks and drops\u003cbr\u003e - pollution and dust\u003cbr\u003e - direct sunlight\u003cbr\u003e - heat and cold\u003cbr\u003e - When the appliance is not going to be used for a longer period of time\u003cbr\u003e the batteries must be removed\u003cbr\u003e\u003cbr\u003e WARNING: The results measured with this device do not constitute a diagnosis. They do not replace consultation.\r \u003cbr\u003efrom a doctor, especially if the symptoms don't match. Don't rely solely on the measurement result; always consider other symptoms and the patient's feedback. If in doubt, always contact your doctor.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eOther information\u003c\/b\u003e\u003cbr\u003e Medical device. Read the instructions for use before use.\u003cbr\u003e\u003cbr\u003e \u003cb\u003eManufacturer \/ Distributor\u003c\/b\u003e\u003cbr\u003e Microlife AG ​​Swiss Corporation,\n Espenstrasse 139,\n 9443 Widnau,\n Switzerland","brand":"Microlife","offers":[{"title":"1.00 Stuks","offer_id":58202574913881,"sku":"225702","price":55.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0971\/4843\/6825\/files\/4719003402914_A1N1.png?v=1780494847","url":"https:\/\/cleanpharma.nl\/en\/products\/microlife-non-contact-thermometer-nc200-1-stuks","provider":"CleanPharma","version":"1.0","type":"link"}